Perimeter Fire Containment Solutions for Today’s Advanced Curtain Wall Systems
- Home
- Markets We Serve
- Curtain Wall
The Curtain Wall & Facades Experts
STI is the global leader in perimeter fire containment systems tested to ASTM E 2307 for sealing the void area between a fire-rated floor and non-rated exterior wall. With over 150 Published design listings providing solutions for a multitude of framing and facade types, STI is the clear leader in real world published design listings for today’s advanced curtain wall systems. Our extensive catalog of tested designs combined with our industry leading team of Curtain Wall & Facades experts are here to support you on your next project, ensuring fire performance without compromising your buildings aesthetic.
Fire containment System for Valance Insulated Panel, Non-Backpan Designs.
We are excited to introduce the firestop industry’s first perimeter fire containment system for valance insulated panel, non-backpan designs. This cutting-edge design listing is a cost-effective, “all vision glass solution” that can be installed in the shop or on-site or as a new install method for traditional insulated spandrel areas.
- Cost-effective All Vision Glass solution that can be installed in the shop or on-site
- Allows lower section of spandrel area to be insulated for thermal or uninsulated
- Multiple spandrel types including vision glass, glass, stone, ACM, and MCP panels
- Designs allowing structural silicone in addition to pressure plate/gasket
- Anchor shielded from direct flame impingemen
- Class II or III Movement Capability - +/-5% Vertical Shear
- Less than 1 CFM L rated
- Specs call for minimum 3” thick 8 pcf faced or unfaced ROCKWOOL CURTAINROCK 80 insulation
- 2 Hour Rated
Designs for Steel Stud and Rainscreen Conditions
Rainscreen conditions represent a unique design challenge when it comes to maintain fire resistance ratings. Ventilation gaps and drainage critical to protect the structure from forming mold can just as easily allow for flame and smoke propagation floor to floor during a fire event.
STI offers a complete package of tested perimeter fire barrier designs that maintain fire resistance ratings without interfering with ventilation and drainage.
Curtain Wall Solutions
STI is the global leader in developing perimeter fire barrier systems for sealing the void area between a fire-rated floor and non-rated exterior wall. . Our solutions are designed to meet the criteria of ASTM E2307 testing while being field installable and accommodating for modern design aesthetics and trends.
Watch More VideosDesign Assist Services
Design Services
Curtain Walls are the most prominent aspect of any building and one of the most challenging elements to work with from a fire resistance perspective.Let our team of Curtain Wall and Facades Firestopping experts assist by reviewing your design and provide appropriate recommendations to ensure performance under fire without compromising on your design aesthetic.
Perimeter fire containment systems are tested according to ASTM E2307, "Standard Test Method for Determining Fire Resistance of Perimeter Fire Barriers Using Intermediate-Scale, Multi-Story Test Apparatus (ISMA)".
The ISMA structure is a two-story furnace that subjects a perimeter fire containment system to fire exposure from two sides simultaneously
One published design listing covers insulated spandrel panel, valance insulated panel, and zero spandrel/all vision glass designs that can be field or shop installed!
STI manufactures two grades of elastomeric firestop coatings:
SpecSeal® AS Elastomeric Spray is a latex-based firestop spray formulated for high movement and rate of application
SpecSeal® Series FT Fast Tack Firestop Spray, a hybrid polymer coating designed for use in inclement weather
The Quick Clip™ Perimeter Fire Containment System is designed to accelerate the installation of curtain wall spandrel insulation. The system's unique U-brackets clip onto mullions without screws to support the curtain wall insulation. Self-locking fasteners secure the insulation panels in place.
Tools & Resources
We’ve curated an extensive collection of tools and resources tailored to meet the specific needs of professionals in the industry. Our assortment focuses on functional tools and references for Firestop solutions, providing professionals with the knowledge, guidance, and tools necessary to ensure safety, compliance, and precision in their projects, ultimately enhancing the integrity of their construction work.
- Guided search for finding the right firestop system for your condition and building Firestop Submittals for submission to your AHJ
- Find firestop systems on your phone, tablet, or the web
- Streamlined firestop system submittal package
- Integrate user documents, company logos, and Engineering Judgements
Estimate the type and number of Quick Clips needed for your next build
Track fire life safety systems on your project via your tablet, phone, or web browser.
Find any and all LEED Credits associated with our firestop products in one place
The Firestop University gives you access to all of STI’s learning material and product tutorials.
Access Guide Specifications for products or solutions for common Firestop issues.
These powerful tools guarantee the right systems are selected for the fastest and most cost-effective installation for all your projects.
Fast Tack Firestop Spray Installation
FastTack® Firestop Spray is the ultimate in weather resistant firestop sprays. FastTack®’s hybrid copolymer formula was developed to counter the stalling effects of weather while providing unmatched washout resistance and the industry’s fastest tack free times.
Perimeter Fire Containement Brochure
Protect your creative visionwith real world firestop solutions.
STI BPF120-09 Quick Clip Field Training Sell Sheet
One published design listing covers insulated spandrel panel, valance insulated panel, and zero spandrel/all visionglass designs that can be field or shop installed!
SpecSeal Quick Clip Field Installation Savings Calculator
QuickClip is the fastest method of installing spandrel insulation in the field of any tested systems!It reduces or eliminates the use of steel screws into framing members.